Technical Data
Dimensions | Medium | Large |
---|---|---|
Overall dimensions | 42cm x 57cm x 9cm | 52cm x 77cm x 9cm |
Mounting dimensions | 38cm x 53cm ±1cm | 48cm x 73cm ±1cm |
Inner width | 20cm x 30cm | 30cm x 50cm |
Component thicknesses | ||
Standard | 2cm - 10cm | |
with optional Spacer | ≤ 2cm | |
with optional Tunnel | 10cm - 75cm | |
Thermal insulation | Economy | Passive House |
thermal transmittance | 0,811 W/(m²K) | 0,523 W/(m²K) |
Air tightness according EN 12207 - 1999–11 | ||
Class 4 | ||
Driving rain resistance according to EN 12208 - 1999–11 | ||
ClassE1050 | ||
RFID (Animal ID) | ||
Implanted or external Transponders per ISO standards 11784 / 11785 FDX-B | ||
Range with implanted transponders | 0-15cm | |
Range with collar tag transponders | 15-30cm | |
Burglary resistance | ||
Through a contactless access control system Through a built-in alarm system | ||
Through a contactless access control system By integrating into existing alarm systems | ||
Through a contactless access control system By using WK2 certified hardware and high-strength materials |
Climatic conditions | ||
---|---|---|
Inside | 0°C to +40°C | |
Outside | -40°C to + 85°C | |
Power supply | ||
Input voltage | 90-264V AC | |
Output voltage | 24V DC | |
Base load | 0,2A | |
Cable length | 1,8m | |
Accu Pack | 12V 0,8A | |
Clock backup battery | CR3220 | |
Sensors | ||
Capacitive movement sensors | ||
PIR movement sensors | ||
Light sensor | ||
Rain sensor (optional) | ||
IR-Receiver | ||
Reed contact | ||
Secondary Reed contact (optional for door assably) | ||
Interfaces | ||
Output for external alarm systems | ||
Serial interface |